Chimney Liner Installation in Hawthorne for Gas Appliances

Book Chimney Liner Installation

What the Job Covers

A liner is the pipe or tile that carries exhaust up through the brick. Clay tile cracks in quakes and from heat, and an oversized flue on a gas furnace or water heater can run so cool that wet exhaust condenses and eats the mortar. We camera the flue, work out the diameter the appliance needs, feed in a stainless liner, connect it at the bottom and seal it under the cap.

Camera check of the old flue first
Diameter worked out from the appliance rating
Stainless liner fed down from the roof
Connection made at the insert, furnace or heater
Wrap added if the flue sits close to framing
Top plate and rain cap fitted to finish

Why Gas Exhaust Is Hard on an Old Flue

Many brick chimneys around Hawthorne were built with a clay tile flue sized for a wood fire, a wide square passage meant to carry a lot of smoke. Gas exhaust is a smaller, cooler stream, and it carries a lot of water vapor. Send it up a big cold clay flue and it slows, cools and condenses on the tile. That moisture is mildly acidic, and over years it eats the mortar between the tiles and the tiles themselves, which is why chimneys that serve a gas furnace or water heater can decay from the inside while the outside looks fine. It also weakens the draw, so exhaust can linger and spill back. A cracked tile, which many chimneys have after a quake, lets that exhaust leak into the masonry and sometimes into the house.

The usual fix is a new stainless pipe sized to the appliance, fed down the existing flue and connected at the bottom. A sealed gas insert takes a pair of pipes, one for exhaust and one for outside air, or a single assembly with one inside the other. A gas furnace or water heater flue takes a single smaller pipe, often insulated so the exhaust stays warm and rises. Up top, a steel closure covers the old tile around the new pipe and a cap goes over both, so rain and animals cannot get between them. Wood stoves and pellet stoves have their own liner rules, and we size those too. What decides the liner is the appliance, not the chimney: change the appliance and the liner may need to change with it.

Before, During and After a Relining

A liner is never sized from the roof alone. We start with the appliance, its maker's venting instructions and its output, then look at the flue it will run through, usually with a camera, since an offset or a collapsed tile can stop a liner partway down. That is often the Level 2 inspection, $380 here, which also tells you whether the old flue can stay as it is. Then the written quote: liner size and type, whether it is insulated, how it connects at the bottom, the work to clear the damper area if a fireplace is involved, and the closure and cap at the top. Height, liner size and roof access drive the figure, so two jobs on the same street can differ, and the quote names each piece so you can see why.

On the install day the gas to the appliance is shut and the appliance disconnected. The liner goes in from the roof, fed down the flue, and is connected at the bottom to the insert, the furnace connector or the fireplace. After the top is closed, the appliance goes back on, the gas is reconnected and leak tested, and we run it while checking the draft and the carbon monoxide level. A water heater or furnace sharing the chimney with a fireplace gets its own liner, never a share of the fireplace one. A liner is also the usual partner of a gas insert, and if you are planning one, the vent pipe is in the insert's price. Owners in Hawthorne, Inglewood and Lomita who have been told their flue needs relining can book a visit through the contact page; mention what the chimney serves now.

How Dooley Chimney Group Works

Metered, Not Guessed

Gas parts tested before any swap

CO Reading

Taken at the end of every gas visit

Price on Paper

Each repair priced before tools come out

Photos in the Report

Findings shown, not just listed

Towns we drive for chimney liner installation

Search your town. Focus cities open a page with local housing and weather notes; the rest link to the town overview.

Full town list

Nothing on the list by that name. Try the next town over, or send your address through the contact page.

Related Services

Chimney Sweep

Wood-burning flues brushed clear of soot and glaze, the smoke shelf scraped, and a note on anything the brushes uncovered.

Details →

Chimney Inspection

A ranked look at crown, flue, damper and firebox, with gas connections and vent paths included whenever a gas appliance shares the chimney.

Details →

Chimney Repair

Cracked crowns, open mortar joints and broken flue tile repaired, scoped in writing first so you know which faults touch the gas appliance.

Details →

Fireplace Inspection

Room-side check of firebox, damper, hearth and surround, plus the gas valve, burner and glass when the fireplace runs on gas.

Details →

Fireplace Repair

Cracked panels, loose firebrick, worn doors and smoke spilling into the room, each traced to the faulty part before anything is ordered.

Details →

Chimney Level 2 Inspection

Camera survey of the full flue for a sale, a new gas appliance or a quake, recorded and written up for whoever needs it.

Details →

Chimney Cap Installation

Stainless caps with spark mesh, measured to the flue tile, fastened for Santa Ana gusts and matched to gas or wood exhaust.

Details →

Chimney Flashing Repair

Leaks at the roofline traced and stopped with new step and counter pieces cut into the mortar, not smeared over with sealant.

Details →

Chimney Masonry Repair

Sandy joints, flaking brick faces and white salt stains on the stack repaired with mortar and brick that match the old work.

Details →

Chimney Rebuilds

A leaning, shifted or cracked stack taken down and laid back up, with steel or a framed top where the city calls for it.

Details →

Fireplace Cleaning

Room-side cleanup of firebox, grate, glass doors and smoke-stained brick or tile, kept apart from the sweep that works inside the flue.

Details →

Gas Fireplace Cleaning

Yearly gas hearth service: burner ports cleared, pilot and sensor cleaned, glass film lifted, logs reset and the vent checked for draft.

Details →

Gas Fireplace Repair

Pilot outages, igniters that tick without lighting, weak flames and dead remotes, traced with a meter through the parts in firing order.

Details →

Fireplace Remodel

New faces, mantels and gas conversions drawn up around the clearances your firebox and vent actually allow.

Details →

Fireplace Inserts

Sealed gas or wood boxes fitted into an existing opening, with a new liner to the top so the heat stays in the room.

Details →

Pellet Stove Repair

Pellet stoves that stop feeding, fail to light or shut down on a fault code, repaired after a test of each motor and sensor.

Details →

Wood Stove Repair

Door ropes, baffles, firebrick and catalytic combustors on wood stoves replaced so the stove seals and burns at the rate it should.

Details →

Gas Logs

Ceramic log sets over a gas burner, picked for your firebox and room, piped in and laid out so the flame burns clean.

Details →

Chimney Seismic Retrofit

Brick stacks braced, strapped or rebuilt lighter above the roof so a strong quake is less likely to drop bricks on the house.

Details →

Chimney Crown Repair

Cracked or crumbling crowns sealed, patched or poured new with an overhang that throws rain away from the face of the stack.

Details →

Dryer Vent Cleaning

Lint packed into the duct between dryer and outside hood cleared, so loads dry on one cycle and the duct stops running hot.

Details →

Chimney Leak Repair

Water in the attic, a wet ceiling or a rusted damper traced to its entry point and stopped, priced once the source is known.

Details →

Chimney Waterproofing

Breathable water repellent on brick and mortar that drinks rain, applied after cracks and joints are repaired, never over them.

Details →

Chimney Damper Repair

Rusted, warped or seized dampers freed, rebuilt or swapped for a top-mounted unit, with a stop fitted when gas logs share the firebox.

Details →

Chimney Chase Cover

Rusted chase tops on factory-built fireplaces replaced in stainless, shaped to shed water and sealed where the vent pipe passes through.

Details →
Call (323) 524-5172